C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

SKU
CFP708-4
£193.91 £161.59
C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)
<span style="color: Chocolate;">Limited Stock</span> Limited Stock

Product Details for C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

LPCB certified to EN54-2/4, C-TEC's CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.


Key Features of the CFP708-4

> Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
> Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
> Manufactured by C-TEC in the UK.
> Eight detector zone circuits.
> Four conventional sounder circuits.
> Integral 1.5A EN54-4/A2 compliant switch mode PSU.
> Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
> Two on-board relays (Fire and Fault).
> Two open-collector outputs (Remote and Reset).
> 'Class change' and alert inputs.
> Installer-friendly design.
> Attractive flush or surface mountable plastic lid and enclosure - no bezel required.
> Low 25mA quiescent current.
> Multiple indicators.
> System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
> Space for two x 12V 3.3Ah VRLA batteries.
> Fully compatible with C-TEC's ActiV range of conventional fire detectors.

More information about C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

More Information
Brand C-TEC
Manufacturer Part No. CFP708-4
Primary Power Source Mains Powered (230V)
System Type Conventional
Number of Zones 8
Warranty 1 Year
Write Your Own Review
You're reviewing:C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)
Your Rating

Datasheets and Manuals for C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

FAQ’s for C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for C-TEC CFP 8 Zone Conventional Fire Alarm Panel (CFP708-4)

Approvals/Certifications Certified to EN54-2/4 by the LPCB (176b)/(0832-CPD-1704)
Mains Supply: 230V 50/60Hz
Mains rated current: 350mA maximum
Internal Power Supply: 19V-28.5V (27V nominal). Ripple 7V maximum (battery fault)
Total output current limited to: 1.5A @ 230Vac (ImaxA eq 146mA)
Quiescent Current: 25mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Max. battery size and type: 2 x 12V 3.2Ah VRLA connected in series. Min. battery size 1.2Ah
No. of detector zone circuits: 8 (Max. length per circuit is 500m)
Call Point Resistor Value: 470 to 680Ω.
Max. devices per detector zone: 25 detectors (or 32 detectors/manual call points combined)
No. of conventional sounder circuits: 4 (Max. length per circuit is 500m)
EOL Resistor Value: 6800Ω 5% Tol. 0/2W (blue, grey, red, gold)
Alarm Voltage: 27V max, 20V min (final battery voltage)
Max. sounder output current: 4 x 200mA (800mA total)
Auxiliary Relays: Two: (1) Aux/ Fire; (2) Fault. Volt frree single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Open collector outputs: Two: (1) Reset (Active during reset cycle); (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max. sink current 30mA, Max. open circuit voltage 27Vdc).
Other outputs: 24V Aux. Power (Protected by a resettable fuse. 100mA min. hold current. Resets when fault removed).
Auxiliary inputs: Two: (1)'Class Change' (constant sounders); (2) Alert (pulsed sounders). Connect to 0V to trigger, Max. input voltage 27V (non-latching).
Engineer (AL3) functions: Program coincidence (double knock); Invoke One Man Walk Test; Program delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities.
Expansion connections: Yes - for optional network driver cards (one required per repeater system), relay output cards and EN54-13 sounder circuit interface boards.
Product Dimensions (mm): 380 W x 235 H x D 96mm
Construction & Finish: Plastic lid and base; RAL7035 textured.
IP Rating: IP30.
Weight: 1.75kg (without batteries).
Operating Conditions/Temperature: -5°C to 40°C. Max relative humidity: 95%