This website uses cookies to ensure you get the best experience on our website. Read our cookie policy
SKU
177401
£49.67 £41.39
Ziton ZP755R-2R Addressable Room sounder c/w cover
The Ziton ZP755R-2R is a red, addressable, loop powered room sounder for use with ZP fire alarm systems. It combines a detector base and audible sounder in a single, stylish moulding.
Developed for applications in individual rooms, sleeping accommodation or small compartments where it is impractical or unnecessary for the sounder and detector to be combined. Installed directly onto a ZP7 wiring loop - the ZP755R-2R enables the system designer to offer a complete addressable system on a single pair of wires. Installation costs are reduced, whilst system integrity, sounder options and programmed alarm organisation are increased. The moulding plugs directly into a first-fix base, eliminating the need for any wiring directly to the device.
High efficiency acoustic design and a low energy sound gun transducer enables combinations of up to 60 sensors and 60 sounders to be connected to a 1 km loop of 1.5 mm² cable. In systems where loop lengths or current requirements are excessive, the ZP755R-2R sounder can be locally powered from an external power supply.
Features a unique self-test facility that is automatically activated during routine sounder testing. A built-in microphone circuit measures sound output level and automatically signals the sounder address / location to the control panel, should the output test fail.
Continuous, intermittent and 2-tone outputs are available from which any combination can be chosen to provide alert and evacuate for 2-stage alarms. Sound types comply with most international codes (e.g. BS 5839 Part 1 recommended frequencies). The ZP755R-2R features a sound output of up to 90dBA and a volume control for areas where a reduced sound output is required.
Key Features |
---|
> Powered directly from the ZP loop > Up to 60 detectors and 60 sounders directly on the loop wiring > Plug in base – no direct wiring connections > High efficiency sound gun transducer > Wide range of international sound types and frequencies > EN54:3 Approved and CPR certified |
Manufacturer | Ziton |
---|---|
MPN | 177401 |
Write Your Own Review
Sort By:
No questions yet. Be the first to ask the question!
Code: | 177401 |
Description: | Ziton ZP755R-2R room sounder C/W cover |
Dimensions: | Dia:127mm x H:69mm |
Compatibility: | All ZP7 addressable systems |
Devices per loop (max.): | 60 (1km loop of 1.5mm² cable, 50 m to first device) |
Operating voltage: | Loop powered: 19.5 to 20.5 V Externally powered:18 to 30 VDC |
Sounder: | Output (tone dependant): <70 dB(A) Types: User configurable |
Loop current: | Quiescent (when loop powered): 820µA |
Wiring: | 2 core loop |
Monitoring: | Open/short circuit, sound output, removal, device type |
Addressing method: | 7 way dipswitch |
Operating temperature: | -10 to +60°C |
Storage temperature: | -20 to +70°C |
Relative humidity: | 10 to 95% non-condensing |
IP rating: | IP21C, indoor |
Material: | Moulded thermoplastic |
Mounting: | Surface mount with plug in base - SPB-2R (White) |
Colour: | Red |
Compatible products: | 70802: Red Cap for ZP755B Series Notification Devices SPB-2R: Plug-in Base, RED |
Regulatory: | CPR, EN54-3 certified |
Weight: | 205g |