SKU
ID2/8
£390.00
£325.00
Zeta Infinity ID2 8 Zone Intelligent 2-Wire Fire Alarm Panel (ID2/8)
Available on Backorder
This item is not currently in stock, but it is available to backorder. Contact us for lead time.
Product Details for Zeta Infinity ID2 8 Zone Intelligent 2-Wire Fire Alarm Panel (ID2/8)
The Zeta Infinity ID2 is one of the most advanced 2 wire systems on the market. The Infinity ID2 gives all of the benefits associated with a ‘2 Wire’ installation (less cable, quicker installation, cost savings on labour/product) and has the facility to ‘I.D.’ the devices.
The Infinity ID2 can be used for new installations, as a retro-fit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirable/necessary. This is possible because the Infinity ID2 devices sit on radial circuits, thus making it easy to ‘upgrade’ a system with the facility to I.D. devices without the need to rewire.
Key Features of the ID2/8 |
|---|
|
> The system meets the full requirements of BSEN5839 parts 1 and 6. The control panel has been designed to meet EN54 parts 2 and 4.
> Each device can be uniquely identified by the panel > Device Count Verification > Alarm Verification > 2048 Event History > ID2 Smartphone App available for iOS and Android > Cable Break protection > Cable Short Circuit Protection |
| Brand | Zeta |
|---|---|
| Manufacturer Part No. | ID2/8 |
| Product Series | Infinity ID2 |
| Primary Power Source | Mains Powered (230V) |
| System Type | 2-Wire |
| Number of Loops (Fitted) | 1 |
| Number of Zones | 8 |
| Protocol Compatibility | Zeta MKII |
| Colour | Grey |
| Warranty | 2 Years |
Write Your Own Review
FAQ’s for Zeta Infinity ID2 8 Zone Intelligent 2-Wire Fire Alarm Panel (ID2/8)
No questions yet. Be the first to ask the question!
Product Specification for Zeta Infinity ID2 8 Zone Intelligent 2-Wire Fire Alarm Panel (ID2/8)
| Product code: |
ID2/8 |
| Description: | Zeta Infinity ID2 8-Zone Panel |
| Dimensions: | W:370mm x H:311mm x D:113mm |
| Supply voltage: |
230V AC +10% /- 15% @ 50/60 Hz |
| Sounder output: |
Loop Powered Sounders 2 x Conventional sounder circuits 28V nominal,150mA (20-30V DC) |
| Fault output: |
1 x Fault Relay SELV@1A (Normally Energised) |
| Fire output: |
1 x Fire Relay SELV@1A |
| No. of zones: | 8 |
| Zone capacity: | 15 devices per zone |
| Max. no. of detection circuits: | Radial Mode - 8 Radial Circuits Loop Mode - 1 Loop Circuit |
| Max. loop sounder quantity: | 80 sounders |
| Repeater connection: |
RS485 |
| Operating temperature: | 0 to 40oC |
| Humidity: | 95% (non-condensing) |