The Kidde AlarmLine AACULP is a PC programmable, Analogue Liner Heat Detection (LHD) cable control unit. It provides monitoring for any of the Alarmline II range of LHD sensor cables, configuration of alarm and pre-alarm temperatures as well as enabling a simple interface to a main fire alarm or BMS system. The AACULP provides LED indications only and requires a PC to configure the control unit. Each control unit may have up to 500m (1640ft) of LHD sensor cable connected to it, acting as a single detection zone. When the LHD sensor cable and the control unit are installed in different areas, a suitable interposing cable can be used to make the electrical connection between them.
Key Features of the AACULP |
|---|
|
> UL521 and CE approval, UL/ULC listed
> Up to 500m of sensor cable per zone > Separate pre-alarm and alarm signals > Easy programmable interface > Enclosure temperature alarm > IP66 rated enclosure > No nomograms or charts required |
| Brand | Kidde Alarmline |
|---|---|
| Manufacturer Part No. | AACULP |
Write Your Own Review
FAQ’s for Kidde Alarmline Analogue LHD Control Unit - PC Programmable
No questions yet. Be the first to ask the question!
Product Specification for Kidde Alarmline Analogue LHD Control Unit - PC Programmable
| Code: | AACULP |
| Description: | Kidde Alarmline II Analogue LHD Control Unit - PC Programmable |
| Dimensions: | W:182mm x H:180mm x D:90mm |
| Operating voltage: | 20 - 28 VDC |
| Current consumption: | Quiescent: < 40 mA Fault: < 40 mA Pre-Alarm: < 50 mA Alarm: < 50mA Pre-alarm & alarm: < 70 mA |
| Detection: | Ambient temp. up to 30°C: Alarm temp. 54°C Ambient temp. up to 47°C: Alarm temp. 64°C / 72°C / 79°C Ambient temp. up to 69°C: Alarm temp. 86°C / 100°C |
| Outputs: | Pre-Alarm (Form C relay resistive load): 2A @ 30VDC / 0.25A @ 250VAC (62.5VA) Alarm (Form C relay resistive load): 2A @ 30VDC / 0.25A @ 250VAC (62.5VA) Fault (Opto-isolated phototransistor output) Max.: 50V @ 20mA |
| Inputs: | Remote reset (isolated) 5s pulse: 20-28VDC |
| Material (body): | Polycarbonate |
| Mounting type: | Recessed mount |
| Environment: | Operating temperature: -0°C to +50°C IP66/IK08, Indoor, Outdoor Relative humidity: 0 to 95% max. noncondensing 75% for <75 m cable & 54°C alarm setting |
| Regulatory: | CE, UL certified |
| Weight: | 735g (net) |