Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

SKU
2X-AT-F2-FB-S
£1,195.76 £996.47
Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)
Available to Order This item is not currently in stock at our main warehouse, but it is available to backorder or may be sent directly from the manufacturer. Contact us for lead time.

Product Details for Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

The 2X-AT-F2-FB-S fire panels supplied in local language, with user interface with fire brigade and fire protection controls, with 2 loops that supports up to 256 devices in 512 zones, have standard 4 supervised sounder/fire-routing outputs, which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs, working in pair and dedicated to common fire and fault conditions, as well as 2 user configurable inputs for monitoring and control are available.

The panel supports one network board to create a maximum of 64 nodes / 256 loops network of fire panels and fire panel repeaters (including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones). Last but not least, in case seperate zone indications are required, a 20 or a 40 zone fire/fault LED indicator board can be mounted in the panel or repeater with ample space for custom text.

High loop power PAK available to increase the loop power from 500 mA to 800 mA.

Compatible with existing loop devices and network compatible with existing panels, repeaters (existing and new) and conventional panels.

The new 2X-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on 2X series learned experience and with complete backwards compatibility, the new 2X-A features an attractive contemporary design that fits with any decor. With improved robustness, manufactured in metal, special plastics and easy electronics removal, it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.

With high power loop addressable detection, a full line of easily configured option cards and modules, as well as USB and Ethernet® connectivity, these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.

This version of 2X-A panels includes a 7 inches touchscreen improving the user experience thanks to the more intuitive user interface.


Key Features of the 2X-AT-F2-FB-S

> 2 High Power Loops with 500 mA per loop and Fire Brigade & Fire Protection controls
> 7" touchscreen
> High loop power PAK increases loop power from 500 mA to 800 mA
> Up to 512 zones, 300 output groups
> Up to 24 LED Zone indicators for Fire & Fault with space for a 4 digit number
> Auto configuration, setup wizards and default regional setup modes
> Ethernet port with TCP/IP for remote diagnostics, maintenance & programming
> EN54 compliant graphical LCD with icons and up to 256 zones
> Improved Jog Dial with 4 soft buttons for intuitive user control
> Painted steel door
> Removable door and chassis
> Pluggable connectors
> Auxiliary 24 VDC supply output with reset support
> 3 USB ports with memory stick support and RS232 for printer support
> Communication via UltraSync cloud, using EN 54-21 UC240 UltraSync communicator
> Integration in management software ATS8600, allowing integration with security systems and CMS
> 3 operator level menu structure (20 usernames and passwords)
> Email notification for events directly from the panel (4 user accounts)
> History log memory for 9999 events
> Backwards compatible, supporting site retrofit/upgrades, expansions, replacement
> Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber

More information about Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

More Information
Brand Kidde Commercial
Manufacturer Part No. 2X-AT-F2-FB-S
Product Series Kidde Excellence Series
Primary Power Source Mains Powered (230V)
System Type Addressable
Number of Loops (Fitted) 2
Max No. of Loops Possible 2
Number of Zones 512
Protocol Compatibility Aritech 2000 Series, Kidde Excellence Series
Warranty 2 Years
Write Your Own Review
You're reviewing:Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)
Your Rating

Datasheets and Manuals for Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

FAQ’s for Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for Kidde 2X-A 2 Loop Addressable Touchscreen Fire Panel with Fire Brigade Controls (Small Cabinet) (2X-AT-F2-FB-S)

Product no.: 2X-AT-F2-FB-S
Description: Kidde Addressable fire panel w touchscreen & fire brigade controls, 2 loops, small cabinet
Dimensions: W:409mm x H:285mm x D:154mm
Form factor: Small
User interface: With fire brigade controls
Max. system capacity: up to 32512 (device count)
Network size: up to 64 nodes
Power supply type: VAC
Operating voltage: 110 / 240 VAC (+10%/-15%)
Mains supply cable type: 3 x 1.5 mm² (live, neutral, earth)
Current consumption: Nom. 0.6 / 1.3 A, Max. 1.5 A / 3.15 A
Loop capacity: 2 max.
Type / rating: 500 mA expandable to 800 mA at 37 VDC (28 to
37 VDC)
Cable rating / type: 52 ohm, 500 nF, max. 2 km / Recommended 2 core 1.5 mm² twisted pair
Outputs: 250mA, 29 VDC (29 - 36 VDC)
Zone capacity: Up to 512 max.
Input quantity: 2
Input type / rating: Supervised, max. load 150 mA
Programmable: 2
Termination: 15 kohm
Fire alarm/fault signalling: 350 mA / 21 to 28 VDC (24 VDC nominal)
Notification: 8 sounder outputs
Supervisory voltage: Supervised, 4, 750 mA / 21 to 28 VDC (24 VDC
nominal)
Auxiliary power: 1 resettable, 500 mA / 21 to 28 VDC (24 VDC
nominal)
Programmable: Up to 8 (2 per loop board) / 21 - 28VDC (24VDC nominal)
Termination: 15 kohm
General Fire + Fault supervised: 2, 350 mA, 19.5 to 28 VDC (24 VDC nominal)
Standby battery: Capacity: Max. 2 x 12 V, 18 Ah (use supplied cables)
Charging: 27.3 V at 20ºC ; 36 mV/ºC
Low battery warning threshold: 23.6 VDC ± 1% at 25ºC
Batteries supported in housing: Max. 2 x 12 V, 7.2 Ah (use supplied cables)
Colour / Material: White (RAL 9003), Steel (painted)
Mounting type: Surface mount
Cable entries: 18 (20 mm) / 2 (20 mm) / 2 removable plates
(top / bottom / back)
Operating temperature: -5 to +40°C
Storage temperature: -20 to +50°C
Relative humidity: 10 - 95% non condensing
IP rating: IP30, Indoor use
Compliancy: CPD, RoHS, WEEE
Certification: EN54-13, EN54-2, EN54-21, EN54-4
Weight: Net: 5.2kg (without battery)
Shipping: 6.6kg