SKU
FIRELINK-400CM
£3,586.20
£2,988.50
Hochiki FIRELINK-400CM 4 Pipe Aspirating Smoke Detector with Command Module
Available to Order
This item is not currently in stock at our main warehouse, but it is available to backorder or may be sent directly from the manufacturer. Contact us for lead time.
Product Details for Hochiki FIRElink 4 Pipe Aspirating Smoke Detector with Command Module (FIRELINK-400CM)
The Hochiki FIRElink-400CM is designed to provide very high-sensitivity smoke detection using an aspirating technique. Unique sensing technology ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex set-up.
With the integrated Command Module this unit also provides a single location display, control and interfacing option for systems of up to 127 detectors and allow global programming of all detector functions simultaneously.
Key Features of the FIRELINK-400CM |
|---|
|
> High sensitivity provided by laser based forward light scatter for reliable early warning
> Four sampling pipes up to 200m (aggregate) in length (still air) > False alarms reduced by unique dust discrimination > RS485 communications for networking and remote communications > Command Module allows control over other FIRElink units on network |
| Brand | Hochiki |
|---|---|
| Manufacturer Part No. | FIRELINK-400CM |
| Product Series | FIRElink |
| Primary Power Source | 24V DC |
| System Type | Conventional |
| Sensor Type | Optical |
| Detectable Medium | Smoke |
| Warranty | 3 Years |
Write Your Own Review
FAQ’s for Hochiki FIRElink 4 Pipe Aspirating Smoke Detector with Command Module (FIRELINK-400CM)
No questions yet. Be the first to ask the question!
Product Specification for Hochiki FIRElink 4 Pipe Aspirating Smoke Detector with Command Module (FIRELINK-400CM)
| Description | Hochiki High Sensitivity Air Sampling Smoke Detector with Command Module |
| Product Code | FIRElink-400CM |
| Dimensions: | W:427mm x H:372mm x D:95mm |
| Supply Voltage: | 21.6 - 26.4 VDC |
| Current Consumption: | 920 mA @ 24 VDC at fan speed 8 |
| Relay Contact Rating: | 500 mA @ 30 V |
| Operating Temperature Range: | 0 to +38 °C (UL268), -10 to + 60 °C (CEA4022) |
| Operating Humidity Range: | 0 - 90% non-condensing |
| Measurement Range (obs/m): | 0.0015% to 25% Full Scale Deflection (FSD) 0.0015% to 25% Sensitivity Resolution |
| Detection Principle: | Laser light scattering mass detection and particle evaluation |
| Particle Sensitivity Range: | 0.003 μ to 10 μ |
| Dust Discrimination Principle: | 3D3 Laser Dust Discrimination (LDD) |
| Maximum Single Sampling Pipe Length/Diameter: | 100m / ¾” nominal bore (27 mm O/D) |
| Total Sampling Pipe Maximum: | 200 m @ 100 sampling holes |
| Alarm Levels: | 4 (Aux, Pre-alarm, Fire 1 and Fire 2) |
| IP rating: | IP50 |
| Sampling Pipe Inlets: | 4 on top, 4 at rear |
| Exhaust Air Pipe Outlets: | 1 on top, 1 at rear |
| Weight: | 5.3kg |