The Hochiki DCD-CE3 is a Rate of Rise Heat Detector with a 90°C fixed temperature element using a thermistor and linearising circuit to provide an accurate linear response Heat Detector.

The DCD-CE3 is ideal for use where medium ambient temperatures exist, such as drying rooms or where Smoke Detectors are unsuitable because of the presence of steam or cooking fumes such as in a kitchen.

The DCD-CE3 is supported by a wide range of bases for different applications and these are supported on the majority of conventional systems.

A third terminal provides remote indicator output.


Key Features of the DCD-CE3(WHT)

> Electronic linear heat detection
> Remote Indicator output
> Wide voltage range (9.5 ~ 30 V dc), can be installed on security systems
> Twin fire LEDs allow 360 degree viewing
> Full range of mounting bases available separately
> Approved by LPCB

More information about Hochiki DCD-CE3(WHT) Conventional Combined Heat Detector 90°C - White Case

More Information
Brand Hochiki
Manufacturer Part No. DCD-CE3(WHT)
Product Series Hochiki CDX
Colour White
Primary Power Source 24V DC
System Type Conventional
Detectable Medium Heat
Warranty 3 Years
Sensor Type Thermistor
Write Your Own Review
You're reviewing:Hochiki DCD-CE3(WHT) Conventional Combined Heat Detector 90°C - White Case
Your Rating

Datasheets and Manuals for Hochiki DCD-CE3(WHT) Conventional Combined Heat Detector 90°C - White Case

FAQ’s for Hochiki DCD-CE3(WHT) Conventional Combined Heat Detector 90°C - White Case

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for Hochiki DCD-CE3(WHT) Conventional Combined Heat Detector 90°C - White Case

Description Hochiki Conventional Combined RoR & Fixed Temperature Heat Detector (90 deg. C)
Product Code DCD-CE3(WHT)
Dimensions (mm): Dia: 100 x H 38
Operating voltage: 9.5 – 30 VDC
Quiescent current (typ): 35 μA
Maximum current alarm: 40 mA
Remote indicator drive: 20 mA (max) / 9.5-14 mA (typ)
Base fixing centres: 48 ~ 74 mm
Approvals: LPCB, VdS (G204045)
IP Rating: IP63
Operating temperature: -10oC to +50oC
Storage temperature: -30 °C to +70 °C
Maximum humidity: 95% RH - Non-condensing (at 40°C)
Colour / Case material: White / Polycarbonate
Compatible bases: YBN-R6, YBN-R/6SK, YBO-R/6R, YBO-R/6RS, YBO-R/6RN, YBO-R/6PA