SKU
CZMU352-IS
£136.12
£113.43
Eaton Cooper Addressable Zone Monitor Unit (Intrinsically Safe) (CZMU352-IS)
Available to Order
This item is not currently in stock at our main warehouse, but it is available to backorder or may be sent directly from the manufacturer. Contact us for lead time.
Product Details for Eaton Cooper Addressable Zone Monitor Unit (Intrinsically Safe) (CZMU352-IS)
When paired with the MTL5561 Opto-Isolated barrier, the CZMU352-IS connects a zone of suitable Eaton conventional detectors and a separate zone of conventional callpoints (if required).
Intrinsic safety refers to equipment and wiring that is inherently safe i.e. a system with energy level so low they cannot cause an explosion. A purpose designed range of intrinsically safe configured interfaces are available to complement the standard range of Eaton products.
Key Features of the CZMU352-IS |
|---|
|
> ATEX compliant
> Soft addressed > Integral short circuit isolator > Single address > Accepts a zone of Eaton conventional detectors > Input monitored for open, short circuit and earth contact faults > Quick and simple to install > No hard addressing required (Plug and play) > Easy to expand a system using existing wiring |
| Brand | Eaton |
|---|---|
| Manufacturer Part No. | CZMU352-IS |
| Primary Power Source | 24V DC |
| System Type | Addressable |
| Protocol Compatibility | Eaton |
| Warranty | 3 Years |
Write Your Own Review
FAQ’s for Eaton Cooper Addressable Zone Monitor Unit (Intrinsically Safe) (CZMU352-IS)
No questions yet. Be the first to ask the question!
Product Specification for Eaton Cooper Addressable Zone Monitor Unit (Intrinsically Safe) (CZMU352-IS)
| Product: | Eaton Addressable Zone Monitor Unit (Intrinsically Safe) |
| Catalogue no.: | CZMU352-IS |
| Dimensions: | W:147mm x H:88mm x L/D:60mm |
| EN Certification standards: | EN54 Pt17 (Short Circuit Isolator) EN54 Pt18 (Input/Output Devices) |
| System topology: | Addressable (soft) |
| Supply voltage: | 18.5V - 30V dc |
| LOOP | |
| Quiescent load current: |
2.8mA |
| Alarm condition load (10 detectors / 10 call points): |
8mA |
| CALL POINT ZONE | |
| No. of call points per zone: |
0 to 10 |
| End of line resistance: |
5k1 |
| Fire input trigger resistance: |
470 Ohms |
| Short circuit fault threshold resistance: | 100 Ohms |
| Open circuit fault threshold resistance: | 39 Ohms |
| DETECTOR ZONE | |
| No. of detectors per zone: | 0 to 10 |
| End of line monitor: | 5k1 |
| Fire input trigger resistance: | 680 Ohms |
| Short circuit fault threshold resistance: | 100 Ohms |
| Open circuit fault threshold resistance: | 39 Ohms |
| Operating temperature: | -10oC to +60oC |
| Humidity (non condensing): | 0 - 95% RH |
| Construction: | PC/ABS |
| IP rating: | IP40 |
| DIN rail compatible: | No |
| Lamp type included: | Halogen free |
| Cable entry: | Rear |
| Colour: | Cream-white (RAL9003) |
| Warranty: | 3 year |
| Weight: |
0.23 kg |