Product Details for C-TEC Emergency only call point, button reset

The C-TEC NC804DE is an Emergency only call point with a call/reset button that can generate emergency calls on an 800 series call system.

Key Features of the NC804DE

> Emergency only call/reset point
> Generates emergency calls on an 800 series call system
> Ideal for use as a reset point for ceiling pull units
> Red reassurance LED confirms call has been made
> Flush or surface mount on std UK 25mm single gang back box
> IP40 rated

More information about C-TEC Emergency only call point, button reset

More Information
Brand C-TEC
Manufacturer Part No. NC804DE
Write Your Own Review
You're reviewing:C-TEC Emergency only call point, button reset
Your Rating

Datasheets and Manuals for C-TEC Emergency only call point, button reset

FAQ’s for C-TEC Emergency only call point, button reset

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for C-TEC Emergency only call point, button reset

Dimensions:
Mounts on 25mm UK single gang back box
W:87mm x H:87mm x D:24mm
Quiescent current: 0mA (none)
Alarm current: Determined by type of control equipment and number/type of field devices connected to  system
Indicators: Red reassurance LED, lit intermittently for emergency calls made on NC804DE and constantly for standard calls made from other devices wired on same zone
Controls: Alert button generates emergency calls, reset button cancels emergency calls from NC804DE or standard calls from devices wired on same zone
Connections: SIG(Signal), -ve(negative), +ve(positive)
Onboard 6.35mm remote jack socket: No.
Onboard infrared receiver: No.
Operating conditions: from -5oC to +40oC, 95% humidity non-condensing
Construction & finish: Plastic
IP rating: IP40