Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

SKU
SA5501-351APO
£70.12 £58.43
Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)
  • Buy 10 for £69.55 £57.96 each and save 1%

Product Details for Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

The Apollo SA5501-351APO Intelligent Open-Area Sounder VID (White Body / Red Flash) is designed for use in open areas and can be connected to any CoreProtocol, Discovery or XP95 system.

The Intelligent Open-Area Sounder VID includes features such as group, global and individual control, status reporting and selectable tone and volume settings, all configured through the fire control panel.

Sounder, visual indicator or both

The Intelligent Open-Area Sounder VID normally switches both sounder and visual indicator to provide an alert or evacuation signal. In situations where a flash or a sounder is not permitted, it is a simple choice as to whether to switch both sounder and visual indicator together or to switch either as necessary.

The right tone for the installation

The Intelligent Open-Area Sounder VID offers a choice of 15 evacuation tones , including the standard Apollo evacuation tone. A tone is selected during commissioning in order to suit local regulations or customs.

Whichever evacuation tone is selected there is a secondary tone which may be used for alerting or warning of a possible evacuation. 

The right level of sound

The sounder is set during commissioning to one of seven levels of sound, the highest level being nominally 101 db(A) at 1m.

At less than 60 db(A) the lowest level falls outside the scope of the EN54 standard. It has been included to provide a very local warning for the use of personnel in particular environments, such as nurse stations in hospitals.

Addressing

The Open-Area Alarm Devices respond to their own individual address which is set via the appropriate XPERT address card.  Group address and tones on CoreProtocol systems are set using the fire control panel.

Location-specific volume setting

Detectors and sounder indicators are installed in many different types of environment.

When configuring the Intelligent Open-Area Sounder devices the adjustment of the volume can be done at the point of installation.

The commissioning engineer simply sets the control panel to ‘Set-up’* and then walks from one device to the next to set the required volume, using a magnetic wand. When all devices have been set the engineer simply presses a button on the control panel which then registers all the individual volume settings. 


Key Features of the SA5501-351APO

> Adjustable tone and volume (15 tone pairs, seven volume levels)
> Software-defined group addressing with up to 16 group addresses
> Built-in controllable isolator
> Independent control of sounder and visual indicator
> Set-up and testing of devices at point of installation
> Unique acoustic self-test

More information about Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

More Information
Brand Apollo Fire Detectors
Manufacturer Part No. SA5501-351APO
Product Range / Series Apollo Intelligent
Primary Power Source 24V DC
System Type Addressable
Protocol Compatibility Apollo XP95, Apollo Discovery, Apollo CoreProtocol
Colour White
Warranty 10 Years
Write Your Own Review
You're reviewing:Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)
Your Rating

Datasheets and Manuals for Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

FAQ’s for Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

Loading...

 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!

Product Specification for Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)

Code: SA5501-351APO
Description: Sounder Visual Indicator - red flash, white body
Dimensions: 113mm dia. x 65mm deep
Compatibility: Can be connnected to any CoreProtocol, Discovery or XP95 system
Supply voltage: 17 - 35V dc
Digital communication: CoreProtocol, Discovery and XP95
Quiescent current: 890μA
Alarm current, LED on: 8.20 mA
Alarm current at each volume level: Volume 7 8.20 mA
Volume 6 7.50 mA
Volume 5 6.80 mA
Volume 4 6.00 mA
Volume 3 5.30 mA
Volume 2 4.50 mA
Volume 1 3.90 mA (not EN54-3 approved level)
Alarm current VID only: 3.10 mA
Max. sound output at 90º @ 1m: 101 dB(A)
Materials: Housing: White Flame-retardant polycarbonate
Terminals: Tin plated stainless steel
Operating temperature: -10ºC to +55ºC
Storage temperature: -10ºC to +55ºC
Humidity: 0 - 95% RH (no condensation or icing)
IP Rating: IP21C
Weight: 196g
Note: All data supplied subject to change without notice. Specifications
are typical at 24 V, 25ºC and 50% RH unless otherwise stated.
Apollo Intelligent Open-Area Sounder VID (White Body / Red Flash) (SA5501-351APO)