Kentec Sigma CP-A 4 Zone Alarmsense Fire Panel (KA11040M2)

SKU
KA11040M2
£301.45 £251.21
Kentec Sigma CP-A 4 Zone Alarmsense Fire Panel (KA11040M2)

The Kentec Sigma CP-A (KA11040M2) is a 4 zone Alarmsense two-wire fire alarm control panel which is compatible with all Apollo Alarmsense two-wire devices.

The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables, greatly reducing the cabling and installation requirements and hence costs.

The AlarmSense range of devices includes smoke and heat detectors, call points, base sounders, base sounder/beacons and relay units – all wired to the same pair of cables.

Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common, zonal or two-stage alarms by simply setting one of the panels configuration options.

Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode, alarms are restricted such that only the sounder connected to the activated detector will operate initially. The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset, a general alarm will sound throughout the premises.

The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure, high quality fire protection throughout the premises.


Key Features
> Allows systems to be installed in accordance with BS5839: Part 6: 2013 installations
> Two-wire systems, reduces installation cabling
> Two-wire repeaters and ancillary boards via serial bus
> Fully programmable using simple menu options
> Adjustable sounder delay time
> Sounder configuration options
> Zonal sounder delay for detectors only
> Zonal sounder delay for call points only
> Coincidence output via ancillary board
> Short circuit fire selectable by zone
> Non-latching selection by zone
> Silent zones (common sounder outputs)
> Zone input delay for sprinkler system connection
> AlarmSense® local alarm feature supported
> Simple, single board construction
> Installer friendly
> Compatible with all Apollo AlarmSense® devices
> Two conventional monitored sounder outputs
> 3 Amp power supply
> Auxiliary power output
> Kitemarked and certified to BS EN54-2 and BS EN54-4
More Information
ManufacturerKentec Electronics
MPNKA11040M2
Write Your Own Review
You're reviewing:Kentec Sigma CP-A 4 Zone Alarmsense Fire Panel (KA11040M2)
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
Construction1.2mm mild sheet steel
IP RatingIP30
FinishEpoxy powder coated
Colour - lid & boxBS 00 A 05 grey - fine texture
Colour - control panel & labelsRAL 7047 light grey - satin
Dimensions385mm x 310mm x 60mm
Weight6kg
Supply Voltage (K models)230V AC (+10%/-15%)
Mains Supply Fuse1.6A 250V
Power Supply DC rating24V 3 Amps
Maximum battery size7aH 12V (2 per panel)
Fault contact rating30V DC 1 Amp
Local fire contact rating30V DC 1 Amp
Fire contact rating30V DC 1 Amp
Common Sounder output rating0.5A per output (max 1.6A over all outputs)
Alarmsense Sounder output rating0.2A per output
Detection zone current1.6 milliamps
Detection zone EOL resistor3K3 5%
Sounder output EOL resistor10k 5%
Cable capacity2.5mm² per terminal
Operating temperature-5°C to +40°C
Operating humidity<95% (non condensing)
Kentec Sigma CP-A 4 Zone Alarmsense Fire Panel (KA11040M2)