C-TEC ActiV Weatherproof Hi-Output Wall VAD c/w Voice Sounder (BF447C/CC/DR/65)

SKU
BF447C/CC/DR/65
£97.78 £81.48
C-TEC ActiV Weatherproof Hi-Output Wall VAD c/w Voice Sounder (BF447C/CC/DR/65)

The ActiV Hi-Output range of conventional voice sounders and combined voice sounder visual alarm devices (VADs) are designed for use with C-TEC’s range of conventional fire panels (CFP, FP/ MFP, EP203) and other compatible third-party panels. However, compatibility testing with third-party panels is recommended to ensure correct operation.

With a 100 dB(A) peak sound output @ 1 m, their purpose is to visually and audibly alert building occupants of a fire alarm. Units are supplied with either a shallow or deep base, in a red plastic enclosure.

The devices offer low current consumption, high sound output, high efficiency VADs, four selectable tones, two selectable evacuation voice messages, two selectable volume levels and three selectable VAD flash rates. Tones, messages, volume levels and VAD flash rates are selected using the device’s 8-way DIP switch.

All devices are designed to comply with the relevant sections of the fire alarm device standards EN 54-3 (Sounders) and EN 54-23 (Visual alarm devices - VADs).


Key Features
> Provides 'W-2.75-9' rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Can also be used as a W-4-4 VAD.
> Superb sound intelligibility.
> Choose from two evacuation voice messages and four evacuation alarm tones (your selected evacuation message will be preceded by the selected tone).
> Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
> Alarm Current at 30Vdc = 17mA (0.5Hz) or 24mA (1Hz)
> Alarm Current at 18Vdc = 18.5mA (0.5Hz) or 30mA (1Hz)
> IP55C rated (weatherproof).
> Manufactured in the UK by C-TEC.
More Information
ManufacturerC-TEC
MPNBF447C/CC/DR/65
EAN5056059612959
Write Your Own Review
You're reviewing:C-TEC ActiV Weatherproof Hi-Output Wall VAD c/w Voice Sounder (BF447C/CC/DR/65)
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
Protocol/Compatibility:Compatible with C-TEC's CFP, FP, MFP and EP203 conventional fire alarm panels and virtually all other makes (testing on third-party panels is recommended before use)
Application/Operation:Designed to be wall mounted. Can be used in covered outdoor areas.
VAD category & coverage:W-2.75-9 rated light distribution (min 0.4 lux over a 2.7.5m x 9m cuboid area). Can also be used as W-4-4 VAD.
Flash rate & colour:0.5Hz; 1Hz or OFF / White
Supply/Operating Voltage:18 to 30V DC
Alarm Current:At 30Vdc: 17mA (0.5Hz) or 24mA (1Hz); At 18Vdc: 18.5mA (0.5Hz) or 30mA (1Hz)
Product Dimensions (mm):114mm diameter x 132mm deep
IP rating:IP55C (Weatherproof)
Weight:315g
Operating conditions/temperature:-10ºC +55ºC. Max. 95% RH (Non-condensing)