C-TEC Hush ActiV Grade C Domestic Fire Alarm Kit (HAK/1)

SKU
HAK/1
£241.18 £200.98
C-TEC Hush ActiV Grade C Domestic Fire Alarm Kit (HAK/1)
A new Grade C domestic fire detection and alarm system to BS 5839-6 (2019) for use in individual flats, houses and apartments.

The HAK/1 Kit Includes:

  • 1 x Double Gang Hush-ActiV Controller c/w 72 hour standby battery 
  • 1 x Double Gang 230V/24V 250mA PSU
  • 1 x ActiV multi sensor
  • 1 x ActiV smoke detector
  • 1 x ActiV 60ºC heat detector
  • 3 x ActiV diode detector bases
  • 1 x ActiV base sounder 
  • 1 x lid for base sounder

Optional decor plates available for use with ceiling mounted ActiV devices to cover the decorating marks left when used to retrofit older Grade D alarm devices.

Watch the Video

Why Hush-ActiV?

SAFER
Raises the typical level of fire protection in a dwelling from BS 5839-6 Grade D (unmonitored Mains/Battery Alarms) to Grade C (monitored wiring and a central controller)

EASY-TO-ACCESS USER CONTROLS
No need to stand on a chair to Test or Hush/Silence devices

SECURE MONITORED WIRING
All field wiring monitored for open and short circuit faults

ENVIRONMENTALLY FRIENDLY
Up to 50% reduction in the mains power consumption of a typical Grade D system, less plastic and only one replaceable lithium-ion battery per system providing over 72 hours standby

REDUCED LIFETIME OWNERSHIP COSTS
Separate fire detectors and sounders are less expensive to replace than Mains/Battery Alarms and all smoke detectors have built-in drift compensation to increase service life expectancy

NO INTRUSIVE BS 5839-1 MAINTENANCE VISITS
Monthly user/occupant test is sufficient

DIRECT GRADE D SYSTEM UPGRADES
Utilises the same wiring scheme as most Mains/Battery Alarm solutions

Hush-ActiV Operation

Press HUSH when there is an Unwanted Alarm to silence the system for 2 minutes (extendable by a further 2 minutes if the Alarm has not cleared). Press TEST for 3 seconds when the system is in its normal state to briefly sound the Alarm sounder(s). BS 5839-6 2019 recommends this test is carried out by occupants at least once a month.

Press HUSH when a wiring or battery fault is detected to silence the fault buzzer for 24 hours. Occupants should report the fault to the responsible person/service engineer at their earliest convenience.

Press HUSH when the system is in its normal state to deactivate alarm detection for 15 minutes (’hot works’ function).


Key Features
> Grade C domestic fire detection & alarm system to BS 5839-6 (2019) for use in individual flats, houses and apartments
> Supplied as a cost-effective kit for ease of specification.
> Easily accessible HUSH and TEST buttons
> Monitored for battery, power supply, detector removal & open/short circuit faults.
> Low-level system controller facilitates compliance with the Equality Act.
> Attractive double gang Hush-ActiV controller comes with non-latching fire and fault outputs, a trigger input, a rechargeable 72 hour standby battery and a separate mains power supply unit
> Uses attractively designed EN54 certified detection and alarm devices
> Only one 10-year replaceable standby battery per system (supplied)
> Each kit includes all of the devices you need to create a typical LD2 dwelling system - additional ActiV detection and alarm devices are also available to accommodate larger systems
> Can be used in any situation where Grade D Mains/Battery Alarms are specified.
> Kits with a different mix of fire detectors also available.
More Information
ManufacturerC-TEC
MPNHAK/1
EAN5056059613277
Write Your Own Review
You're reviewing:C-TEC Hush ActiV Grade C Domestic Fire Alarm Kit (HAK/1)
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
CompatibilityCompatible with C-TEC's ActiV range of conventional fire alarm devices. For the contents of this kit, see Kit Contents section below.
Total output current limited to100mA
Battery charge capacity2Ah.
Quiescent current5mA.
Max battery size and type2Ah Li-Ion battery supplied (replaceable, up to 10 year life).
No. of detector zone circuits1.
No. of conventional sounder circuits1.
Indicators4 x LEDs on Hush Controller: Supply (green); Fault (yellow); Alarm (red); Hushed (amber).
Controls1 x TEST button; 1 x HUSH button.
Expansion connections1 x unmonitored open collector Fire output (follows the dwelling's sounders but ignores system Tests); 1 x unmonitored open collector Fault output; 1 x unmonitored Alarm trigger.
Onboard SounderYes. Provides audible feedback of a fire/fault condition.
Product dimensions (mm)Hush Controller: 146 W x 85 H x 25 D mm (Can be mounted on a standard UK 35mm double gang flush or surface back box).
Construction & finishSupplied on a double gang plastic plate.
IP RatingIP40.
Weight160g.
Operating conditions/temperature-5ºC to +40ºC. Max relative humidity: 95%.
Kit contentsIncludes a Hush-ActiV central controller, a 230V/24V PSU, one ActiV heat detector, one ActiV smoke detector, one ActiV multi-sensor, three ActiV detector bases and an ActiV alarm sounder.