Nittan EV-HIOP-BCN-R-SCI High Output Beacon with -ve Isolator EN54-13 Red Flash

SKU
EV-HIOP-BCN-R-SCI
£89.92 £74.93
Nittan EV-HIOP-BCN-R-SCI High Output Beacon with -ve Isolator EN54-13 Red Flash
  • Buy 10 for £89.21 £74.34 each and save 1%
  • Buy 20 for £88.50 £73.75 each and save 2%
  • Buy 40 for £87.79 £73.16 each and save 2%

The Nittan Evolution EV-HIOP-BCN-R-SCI is a Type B Addressable Outdoor High Output Beacon (Red LED), with integral –ve line Short circuit isolator and is compatible with Evolution analogue addressable system devices.

The device enclosure is waterproof to IP65 rating and is suitable for Indoor or Outdoor installation.

It comes with 3 Beacon Flash settings (1 Approved) to choose from, allowing customers to choose which works best for any installation.

The address may be set using EV-AD2-EXT handheld programmer using the Universal Addressing Lead.

The Short Circuit Isolator will protect the system, whilst allowing the device to continue communication from the opposite side. The isolator will self-reset when the fault clears.

SCI Variant Not compatible with Advanced MxPro4 (Mx4000) Panel. Please use Non-SCI model. It is not possible to mix +ve and -ve isolator styles on a system.

All wiring must conform to the current edition of IEE Wiring regulations and BS5839 Part 1 

All loop Cable Screens shall be connected together, but must be Isolated from Ground. Cable Screens shall be connected to Earth Ground within the Control Panel ONLY.


Key Features
> IP65 rated
> Type B Outdoor Beacon with -ve Isolator
> EEPROM Addressed (Programmer)
> FSK Signalling Protocol
> Beacon Rating W 2.4-5.0 / 60m3
More Information
ManufacturerNittan
MPNEV-HIOP-BCN-R-SCI
Write Your Own Review
You're reviewing:Nittan EV-HIOP-BCN-R-SCI High Output Beacon with -ve Isolator EN54-13 Red Flash
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
Beacon TypeType B Outdoor
Beacon DeviceHigh Power Red LED
Beacon VAD SpecificationW 2.4-5.0 / 60m3
Operating loop voltage24 to 38 Vdc
Quiescent current200 µA
Alarm current20 mA
Current in short circuit13 mA
Operating temperature-25°C to +70°C
Storage temperature-25°C to +70°C
Relative humidity< RH 95% (Non-condensing)
Cable terminals0.75 to 2.5 mm2
MaterialABS
Weight190 g
Dimensions FlushØ104mm x 76.5mm
I.P. Protection RatingIP65
Test StandardsEN54-17: 2005 / AC: 2007
EN54-23: 2010
CPR Certificate0905-CPR-00465
DoP Number00465
Nittan EV-HIOP-BCN-R-SCI High Output Beacon with -ve Isolator EN54-13 Red Flash