C-TEC XFP 1 Loop 16 Zone Addressable Fire Panel (Hochiki ESP Protocol) (XFP501E/H)

SKU
XFP501E/H
£416.98 £347.48
C-TEC XFP 1 Loop 16 Zone Addressable Fire Alarm Panel (Hochiki ESP Protocol) (XFP501E/H)
C-TEC’s XFP single loop 16 zone addressable fire alarm panel offers high performance at a very competitive price.

LPCB certified to EN54 parts 2 & 4, it is supplied in an attractive flush or surface mountable plastic enclosure, offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Hochiki ESP protocol.

Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels, it is one of Europe's best-selling entry-level addressable fire panels.

Packed full of engineering features - some of which are not available on more expensive alternatives (see feature list below) - the XFP501E/X is also fully compatible with C-TEC’s Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.


Key Features
> Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
> Compatibility with Hochiki ESP protocol.
> Two independently programmable conventional sounder circuits.
> Two programmable inputs.
> A fault output relay and three programmable relay outputs with voltage free changeover contacts.
> A selection of zone dependency/coincidence functions.
> A day/night (building occupied/unoccupied) function.
> An investigation delay period function.
> Phased evacuation facility.
> An alarm counter that records how many times the panel has been in alarm state.
> Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
> An integral EN54-4/A2 switch mode power supply.
> Adjustable contamination levels.
> Earth fault monitoring.
> Combined keypad / keyswitch entry to Access Levels 2 and 3.
> 999 event monitoring.
> An intuitive Windows based upload-download PC program.
> Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
More Information
ManufacturerC-TEC
MPNXFP501E/H
EAN5056059607726
Write Your Own Review
You're reviewing:C-TEC XFP 1 Loop 16 Zone Addressable Fire Panel (Hochiki ESP Protocol) (XFP501E/H)
Your Rating
Loading...

Sort By: 

Ask Question

All questions will be displayed after moderation.

No questions yet. Be the first to ask the question!
Approvals/certificationsCertified to EN54-2/4 by the LPCB (0832-CPD-0772).
Protocol/compatibilityHochiki ESP.
Mains supply230V 50/60Hz.
Mains rated current350mA maximum.
Internal power supply27Vdc nominal.
Total output current limited to1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).
Quiescent current50mA (loop unloaded).
Max battery size and type2 x 12V 3.2Ah VRLA connected in series.
No. of loop drivers1.
Max. loop output current500mA (25V min; 34V max).
Max. loop length1KM.
Max. addressable devices per loop126.
No. of conventional sounder circuits2 (Max. length per circuit is 500m).
EOL resistor value6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current400mA.
Auxiliary relays3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Other outputs24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.
Auxiliary inputs2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).
PC connectionPC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.
Indicators2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; System Fault.
ConnectionsFixed, largest acceptable conductor size 1mm2.
Expansion connections2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or 500M (repeater network).
Product dimensions (mm)380 W x 235 H x D 96mm;
Construction & finishPlastic lid and base; RAL7035 textured.
IP RatingIP30.
Weight1.8kg (without batteries).
Operating conditions/temperature-5ºC to +40ºC. Max relative humidity: 95%.